A connection has less than two ports - Intergraph Smart 3D - Administration & Configuration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
12.1 (2019)

Message

A connection has less than two ports.

Severity

Crucial.

Detailed Description

A connection has less than two ports: Missing one or more ConnHasPorts relationship(s) to StructPort for StructPhysicalConnection, AssemblyConnection, StructConnection. In other words, the connection does not have two ports.

Possible Causes

Unknown.

Possible Impacts

Unknown.

What You Should Do

  1. Open the model.

  2. In the Molded Forms task:

    • If it is a user-defined connection, select the connection, and add a port.

    • If it is a generated connection, delete the object. It will automatically be re-created.

  3. Re-run the Check Database Integrity custom command and the DBIntegrity report.

  4. If the object is still posted, contact Smart 3D Support.