Provides a cross-reference to entries in the insulation weight file (IWF) by defining the layout and content of that file.

The INSULATION-WEIGHT-FILE section heading can be followed by the identifiers and associated data listed below:

  • DELIMITER-CHARACTER data - Where data specifies the delimiter used in the insulation weight file, as shown in the following example:

INSULATION-WEIGHT-FILE
DELIMITER-CHARACTER :
INSULATION-SPECIFICATION 1
N.S. 2
INSULATION-WEIGHT 3

  • Start-col. End-col. - Position in the file dependent upon whether a delimiter character is set, as shown in the following example:

INSULATION-WEIGHT-FILE
INSULATION-SPECIFICATION 1 14
N.S. 15 24
INSULATION-WEIGHT 25 34