'PIPING–SPEC’ |
Start Col |
End Col |
‘MIN–N.S.’ |
Start Col |
End Col |
‘MAX–N.S.’ |
Start Col |
End Col |
‘BOLT–UP–TYPE’ |
Start Col |
End Col |
‘TENSION–A’ |
Start Col |
End Col |
‘TENSION–B’ |
Start Col |
End Col |
‘TORQUE–SETTING’ |
Start Col |
End Col |
Start Col and End Col indicate the extremities of each data column in the file.
-
MIN-N.S. and MAX-N.S. must be stated in the units specified at the top of the FDF file.
-
BOLT-UP-TYPE must be one of the following:
-
HT = Hydraulic Tensioner
-
HW = Hydraulic Wrench
-
MW = Manual Torque Wrench
-
NW = Non Mandatory (Hand Tightening)
-
-
TENSION-A, TENSION-B, or TORQUE-SETTING
All entries on the list are triggered by the presence of a Bolt record (-115 type) in the IDF or the attribute BOLT in a PCF.
Each bolted connection is indicated on the isometric drawing using the Drawing Area.Piping Features.Assemblies properties listed below. For more information, see Assemblies in the Isogen Isometric Drawing Options Reference Help.
-
Show Site Assembly Identifier
-
Site Assembly Size
-
Site Assembly Identifiers Per Drawing
-
Site Assembly Style
-
The site assembly uses the AText -478 default value (J) to prefix the flange assembly identification (J1 or JA).
-
An example of the BOLTING-INFO-FILE section is shown below.
BOLTING–INFO–FILE
‘PIPING–SPEC’ 1 12
‘MIN–N.S.’ 15 20
‘MAX–N.S.’ 23 29
‘BOLT–UP–TYPE’ 32 33
‘TENSION–A’ 35 45
‘TENSION–B’ 50 60
‘TORQUE–SETTING’ 65 75