BOLTING-INFO-FILE - Isogen - Help

Isogen Configuration Help

Language
English
Product
Isogen
Search by Category
Help
I-Configure Version
6.0(2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

'PIPING–SPEC’

Start Col

End Col

‘MIN–N.S.’

Start Col

End Col

‘MAX–N.S.’

Start Col

End Col

‘BOLT–UP–TYPE’

Start Col

End Col

‘TENSION–A’

Start Col

End Col

‘TENSION–B’  

Start Col

End Col

‘TORQUE–SETTING’

Start Col

End Col

Start Col and End Col indicate the extremities of each data column in the file.

  • MIN-N.S. and MAX-N.S. must be stated in the units specified at the top of the FDF file.

  • BOLT-UP-TYPE must be one of the following:

    • HT = Hydraulic Tensioner

    • HW = Hydraulic Wrench

    • MW = Manual Torque Wrench

    • NW = Non Mandatory (Hand Tightening)

  • TENSION-A, TENSION-B, or TORQUE-SETTING

All entries on the list are triggered by the presence of a Bolt record (-115 type) in the IDF or the attribute BOLT in a PCF.

Each bolted connection is indicated on the isometric drawing using the Drawing Area.Piping Features.Assemblies properties listed below. For more information, see Assemblies in the Isogen Isometric Drawing Options Reference Help.

  • Show Site Assembly Identifier

  • Site Assembly Size

  • Site Assembly Identifiers Per Drawing

  • Site Assembly Style

  • The site assembly uses the AText -478 default value (J) to prefix the flange assembly identification (J1 or JA).

  • An example of the BOLTING-INFO-FILE section is shown below.

    BOLTING–INFO–FILE

    ‘PIPING–SPEC’         1   12

     ‘MIN–N.S.’           15  20

    ‘MAX–N.S.’            23  29

    ‘BOLT–UP–TYPE’        32  33

    ‘TENSION–A’           35  45

     ‘TENSION–B’          50  60

    ‘TORQUE–SETTING’      65  75