View BOM Information - Intergraph Smart Materials - Version 2020 (10.0) - Training - Hexagon

Smart Materials Web Tutorials 2020 (10.0)

Language
English
Product
Intergraph Smart Materials
Subproduct
Web
Search by Category
Training
Smart Materials/Smart Reference Data Version
2020 (10.0)

The View BOM Information screen can be used by site users to get information about the BOMs.

The list nodes are not populated automatically. To display the list nodes, click the Query Details button. The list nodes appear with the entire BOM path, the Issue Status derived from the related list positions is displayed in the header region of the List Nodes block and the issue progress. The meaning of the issue progress is as follows:

  • None - Nothing has been issued from the list positions material of the selected list node

  • Partly - The material of the selected list node has been issued partly

  • Completely - The material of the selected list node has been issued completely

  • No positions - The selected list node does not have any list positions assigned.

Keep in mind that only those list positions that fit the issue status logic specified in the Setup are considered.

In addition, the Total List Weight, Total Issue Weight, and % Issue Weight values appear.

Click on the hyperlink of List node, to open the List Node Values window. The node attributes of the selected list node with their values are displayed.

Click on the hyperlink of BOM Path, to open List Positions Window, which displays the list positions of the selected list node.

In this window, the list positions with quantity, issued quantity, and reserved quantity are displayed. The progress appears in the Issue Progress field as:

  • None (Issue Qty = 0)

  • Partly (0 < Issue Qty < Quantity)

  • Completely (Issue Qty = Quantity).

Click on the hyperlink of Pos, to open the List Position Values window. The attributes assigned to the selected list position appear with their values under the List Position Values in the left viewing pane.

In related MIRs to List Position block at the right viewing pane, the MIRs associated with the selected list positions are listed with Created On, Posted On, and Issue Quantity details.

To limit the displayed list nodes on View BOM Information, you can define a setup set as a filter. Click the Setup button to open Setup Definition Window.

In this window you can view/maintain Project Specific Setup and User Specific Setup. De-select the Project Specific indicator, to view/maintain User Specific Setup.

Select either the Best Quantity indicator in combination with the Use only Site Status indicator or clear the Best Quantity indicator and select a fixed issue status from the LOV in the Issue Status field.

Select a list status from the LOV in the Minimum List Status field. Only list positions with this list status or a higher list status assigned are considered.

By choosing one of your predefined work packages via LOV in the Work Package field, you can assign the associated work package nodes to your setup set. The nodes are shown in the Assigned BOM List Nodes block below, where you can delete or add nodes manually. Click the Add Nodes button to open the BOM List Nodes multi selection window. Select the check box of all nodes to be added, and then click the Fill In button to close the window and to insert the selected nodes.

After defining the setup, close the window. The Setup Set assigned indicator shows if a setup is defined.

Here, de-select Project Specific indicator to apply user specific setup for calculation rules of properties.