The SimpleWindowAsm sheet in the SimpleDoor.xls workbook defines the windows that you want in your catalog. When creating simple windows, there are custom attributes and required attributes. You can add your custom attributes using the Custom Interfaces sheet (described in the Reference Data Guide.)
Name
Type a name for the window. The name must be unique across the entire catalog.
Part Description
Type a description for the window equipment part.
Symbol Definition
Type the definition of the Visual Basic symbol used to create the window. If you do not enter a value here, the symbol definition defined at the top of the sheet under Definition is used.
Symbol Icon
Enter the graphic to use when displaying a preview of the window equipment part in the Catalog task. If you do not enter a value here, the symbol icon defined at the top of the sheet under Definition is used.
Definition
Type the definition of the Visual Basic class you are creating for the custom assembly definition for the window.
Opening Ratio
Specify the opening rate of the window. Valid values are 1 (Open) and 0 (Closed).
Kinematics
Specify the overall motion of the window. Valid values are defined in the AllCodeLists.xls workbook on the Doors Windows Kinematics sheet in the Codelist column.
Push
Specify the sense of the window panel opening. Valid values are 1 (Push) and -1 (Pull)
Height
Enter the window height in millimeters.
Width
Enter the window width in millimeters.
Top Frame Depth
Specify the depth of the top window frame in millimeters.
Top Frame Width
Specify the width of the top window frame in millimeters.
Lower Frame Depth
Specify the depth of the lower window frame in millimeters.
Lower Frame Width
Specify the width of the lower window frame in millimeters.
Right Frame Depth
Specify the depth of the right window frame in millimeters.
Right Frame Width
Specify the width of the right window frame in millimeters.
Left Frame Depth
Specify the depth of the left window frame in millimeters.
Left Frame Width
Specify the width of the left window frame in millimeters.
Panel Thickness
Enter the thickness of the window panel in millimeters.
X Position
Type the X-position of the window related to the equipment coordinate system.
Y Position
Type the Y-position of the window related to the equipment coordinate system.
Z Position
Type the Z-position of the window related to the equipment coordinate system.
Dry Weight
Enter the empty weight of the window. Be sure to specify the units when entering this value.
Water Weight
Enter the water weight of the window. Be sure to specify the units when entering this value.
Dry COG X
Type the x-axis location of the dry center-of-gravity.
Dry COG Y
Type the y-axis location of the dry center-of-gravity.
Dry COG Z
Type the z-axis location of the dry center-of-gravity.
Water COG X
Type the x-axis location of the wet center-of-gravity.
Water COG Y
Type the y-axis location of the wet center-of-gravity.
Water COG Z
Type the z-axis location of the wet center-of-gravity.
Door Frame Position
Specify the position of the window frame within the specified support. Valid values are defined in the AllCodeLists.xls workbook on the Door Frame Position sheet in the Codelist column.
Distance from Mating Face
Specify the distance between the window and the wall/slab with which it is mated.
Number of Row Panes
Specify the number of row panes present in the window.
Number of Column Panes
Specify the number of column panes present in the window.