The software requires an XML configuration file to perform any kind of post-processing activity. This configuration file contains specific instructions for how the software is to behave during processing. By default, the software delivers a template configuration file, Default.xml, to the [Installation Location]:\SampleIsoDir\SPITutorial\Data\I-Data Integrator\Configuration folder during installation. When you initially open I-Data Integrator, the software retrieves the template .xml file from the default location, loads it, and then opens the I-Data Integrator Main window. If the software is unable to locate the Default.xml file, the software prompts you to specify the configuration file to use.

Because the default configuration file (Default.xml) delivered with the software only contains the initial heading information, you will need to modify to suit your specific post-processing requirements. For more information about the content of the configuration file, see Appendix: XML Configuration File Syntax.

Isogen post-processor

IDIPost.exe is a special application you can run as an Isogen post-processor. You use IDIPost.exe only with Isogen-enabled applications, such as Smart Isometrics and Spoolgen. This post-processor enables the insertion of the FILENAME field into all intrinsic recordsets.

What do you want to do?