The following changes have been made to the Electrical task.
Hot Fix and Service Pack Updates
-
You can now extend a conduit or group of conduits from a duct bank. See Move a conduit end feature from a duct bank. (P2 CP: 345740)
-
When editing duct bank and cable tray properties, the reference point in the lower left corner of the preview on the property dialog is indicated by a blue handle in the model view so you can understand the orientation. See Duct Bank Tab (New Cableway Dialog) and Barriers Tab (New Cableway Dialog).
-
Previously, when you edited the width or depth of a duct bank, the resize was around the center point of the cross section and happened in all four directions. Now the resize happens along the positive X- and Y-axis of the cross section only. In the example below, the width of the duct bank was increased. Note that the duct bank reference point (blue handle) does not move. See Duct Bank Tab (New Cableway Dialog).
-
You can now add conduit rows and columns to existing duct banks. Before, you could only add a single conduit at a time. See Duct Bank Tab (New Cableway Dialog).
-
When branching conduit out of a duct bank, you need only select the conduit end features. Previously, you had to select the duct bank cableway end and the conduit end features. See Branch duct banks.
-
The software now automatically connects collinear conduits when two individual duct banks are connected or when conduit is added at the same position to both duct banks.
-
You can now choose whether or not the duct bank controls the conduit using the Behavior Controlled by User option. See General Tab (Conduit Run Properties Dialog).
12
-
The Route Selection Commands have been expanded to allow the selection of features and runs when a part is selected, or to select the features of a selected run. (P2 CP:295789)
-
You can insert a component in free space as the beginning of a cableway or conduit run. See Insert a cableway component in free space, and Insert a conduit component in free space. (P2 CP:59559)
-
Added a new <Load More Runs> option to the Run box on the Route Cableway Ribbon and Route Conduit Ribbon, and to the corresponding properties' dialogs. See Route Cableway, and Route Conduit Command. (P2 CP:319869)
-
Reporting Type property is now by default determined by specification. See Occurrence Tab. (P2 CP:314160)
-
Quick Route Command now honors user-defined default settings. (P2 CP:315911)
-
Added information about free leg behavior. See Free Leg in Rules for Moving Route Objects. (P1 CP:318434)
You can now defer cable length and tray fill calculations while performing cableway network modifications. See Edit Cableway Straight Feature Ribbon and Edit Cable Path Ribbon (P2 CP:370519)