Distributed load properties are divided into different categories: Standard. You can select the category to define values for by using the Category option.

Standard

Name

Specifies the name of the load.

Name Rule

Select a name rule to use to name the load.

  • Select Default Name Rule to use the following naming syntax: Distributed<Load>-<Workshare Location ID>-<Sequence Number>. For example, DistributedForce-1-0002, where Distributed is hard coded text, Force is the <Load> (either Force or Moment), 1 is the <Workshare Location ID>, and 0002 is the <Sequence Number>, in this case, the second Distributed Force load placed.

  • Select User Defined if you want to name the load yourself in the Name field.

Analysis Parent

Displays the name load's parent object.

Load Case

Select the load case to which the load should be assigned. Create new load cases by using Load Cases Command .

Load

Specifies the direction in which the load magnitude is to be applied. You can place loads in any of the six directions: Force X, Force Y, Force Z, Moment RX, Moment RY, or Moment RZ.

Reference

Specifies the coordinate system reference for the load. For more information, see Learn more about Loads.

Position As

Specifies how the load location is calculated from the start of the member. The location can be defined as Relative or Absolute.

A relative location can be thought of as a distance percentage along the member. For example, a load placed at a relative distance of 0.333 is located at one-third the member length measured from the member start. A load placed at a relative distance of 0.5 is located at the middle of the member.

An absolute distance is the actual distance from the start of the member. The software verifies that the absolute distance that you specify is not past the end of the member.

Start Position

Specifies the start position of the load.

End Position

Specifies the end position of the load.

Start Magnitude

Specifies the force of the load. The magnitude can be a positive or negative value, as needed, and is applied in the direction that you selected in the Direction box.

End Magnitude

Specifies the force of the load. The magnitude can be a positive or negative value, as needed, and is applied in the direction that you selected in the Direction box.