Specification Management - Intergraph Smart Materials - Version 2020 (10.0) - Training - Hexagon

Intergraph Smart Materials Classic Lab Tutorials (2020)

Language
English
Product
Intergraph Smart Materials
Subproduct
Classic
Search by Category
Training
Smart Materials/Smart Reference Data Version
2020 (10.0)

Purpose

This section explains how to create a piping specification with header information.

Exercise

  1. Open the S.50.06 Specification Management screen from Smart Reference Data > S.50 Specification.

  2. If the screen opens in enter query mode, all fields are empty and are displayed with a yellow background. Click the Cancel Query button to change to input mode.

    If the screen opens displaying spec data, click the New Record on the toolbar.

  3. Place the cursor in the Spec Type field, and click the List of Values button to open the LOV. Select the type SDB_TRAIN from the list, and click OK. The LOV is closed, and the selected value is entered in the Spec Type field.

  4. Move to the Spec Code field and type in the spec name from the paper specification. In this example, we will use TRAIN_1CS150.

  5. Click the Spec Header Description tab, and type in a Short Description and a Description for the new spec, for example ‘Class 150, CS’ and ‘Training Class 150, Carbon Steel, 0.063" C.A., Process’.

  6. Save the changes using the Save button.

  7. In the lower block, click the Specification Details tab.

  8. Enter the service, rating class, temperature limit, and corrosion allowance information from the paper specification. The following table is an example of specification details from paper spec 1CS150.

Seq

Tablename

Group

Detail

Short Desc

1

P_Service

ALL

AA

Process

2

P_Rating_Class

ANSI

AA

150, ASME B16.5a - 1998

3

P_Temp_Limit

ALL

AA

-20 to 800F

4

P_Corr_Allowance

ALL

AA

0.063 in (0.05 in MIN)

Enter the sequence manually in the Seq field and use the LOV on the Tablename, Group, and Detail fields to select the required values from the list. Then, click OK to close the LOV and to insert the selected values into the appropriate fields.

  1. Save the changes using the Save button.

  2. Click the Spec Header Geometric tab to move to that tab, and click the Filter check box of the first record.

  3. Enter the short code %, or select it from the LOV in the Short Code field.

  4. Now move to the Table Type field, and open the LOV using the List of Values button to select the type ‘User defined’ from the list.

  5. Then click OK. The selected value will be entered in the Table Type field and the LOV is closed.

  6. Move to the Table Name field, and open the LOV using the List of Values button to select the table name ‘SDB_2CS300_1’from the list.

    Then click OK. The selected value will be entered in the Table Name field and the LOV is closed.

  7. Enter .5 into the From1 field or open the LOV using the List of Values button to select the value from the list.

  8. Enter 24 into the To1 field or open the LOV using the List of Values button to select the value from the list.

  9. Save the changes using the Save button.

  10. Close the screen by selecting File > Close All from the main menu.