What's New in Electrical - Intergraph Smart 3D - Release Notes/Bulletin

Intergraph Smart 3D Release Notes

Language
English
Product
Intergraph Smart 3D
Subproduct
Release Notes
Search by Category
Release Notes/Bulletin
Smart 3D Version
12.1 (2019)

Pretty URL Book with LinkYou can link directly to this document using https://docs.hexagonppm.com/go/S3D121Elec

The following changes have been made to the Electrical task.

Hot Fix and Service Pack Updates

  • When editing duct bank and cable tray properties, the reference point in the lower left corner of the preview on the property dialog is indicated by a blue handle in the model view so you can understand the orientation. See Duct Bank Tab (New Cableway Dialog) and Barriers Tab (New Cableway Dialog).

    Duct Bank Orientation HandleCabletray Reference Point

  • Previously, when you edited the width or depth of a duct bank, the resize was around the center point of the cross section and happened in all four directions. Now the resize happens along the positive X- and Y-axis of the cross section only. In the example below, the width of the duct bank was increased. Note that the duct bank reference point (blue handle) does not move. See Duct Bank Tab (New Cableway Dialog).

    Duct Bank Width Increased

  • You can now add conduit rows and columns to existing duct banks. Before, you could only add a single conduit at a time. See Duct Bank Tab (New Cableway Dialog).

  • When branching conduit out of a duct bank, you need only select the conduit end features. Previously, you had to select the duct bank cableway end and the conduit end features. See Branch duct banks.

  • The software now automatically connects collinear conduits when two individual duct banks are connected or when conduit is added at the same position to both duct banks.

  • You can now choose whether or not the duct bank controls the conduit using the Behavior Controlled by User option. See General Tab (Conduit Run Properties Dialog).

12.1