  1. In the tree view, click Piping > Piping Specification > Piping Materials Classes.

  2. In the Piping Materials Classes branch, open a specification and click Piping Materials Class Rules > Interior Coating and Surface Treatment Rule.

  3. Click the Insert Row Command to insert a blank row in the grid view.

  4. In the Nominal Piping Diameter From column, type the nominal pipe diameter (NPD) that specifies the start of the treatment range.

  5. In the Nominal Piping Diameter To column, type the NPD that specifies the end of the treatment range.

  6. In the Nominal Piping Diameter Units column, type the units for the NPDs. For example, type mm or in.

  7. In the Interior Surface Treatment column, select the interior surface treatment that you want to use for the defined NPD range.

  8. In the Coating Type column, select the coating type that you want to use for the defined NPD range.

The Inside Surface Treatment sheet in the Piping Materials Class.xls workbook corresponds to the Interior Coating and Surface Treatment Rule node in the Catalog task. See Piping Reference Data.