Location from Pump Center, DZ - CAESAR II - Help

CAESAR II Users Guide

Language
Русский
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

Specifies the distance between the nozzle and base point along the Z-axis. Type a positive value if the nozzle Z-coordinate is greater than that of the base point, that is, if the nozzle is farther out on the positive Z-axis.

  • API 610 defines the base point as the center of the pump. The center of the pump is defined as the intersection of the pump shaft centerline and a vertical plane passing through the center of the two pedestals.

  • When analyzing vertical in-line pumps, the software disables DX, DY, and DZ because the coordinates are not used.