Designates a factor by which to increase the operating bolt allowables.
Section VIII Division 2, Article 4-141 of the ASME Boiler and Pressure Vessel Code allows for operating loads on bolts to equal two times the standard table allowables. In some cases, this increase can be by as much as three times the table allowables.