Specifies the soil stiffness perpendicular to the pipe axis on a stiffness per length basis. This stiffness value acts in both directions perpendicular to the pipe. This option is required if Soil Model No. is set to 1; otherwise, leave this option blank.

The smallest allowable non-zero value is 0.5.