Specifies the general configuration of the loop.

Type #1

Places the loop at the From end of the original element in the plane of the Major Direction.

Type #2

Places a 2-D (both dimensions the same size) loop at the From end of the original element, first in the plane of the Major Direction and then in the plane of the Minor Direction.

Type #3

Places the loop in the middle of the original element in the plane of the Major Direction.

Type #4

Places 2-D (both dimensions the same size) loop in the middle of the original element, first in the plane of the Major Direction and then in the plane of the Minor Direction.

Type #5

Places the loop at the To end of the original element, in the plane of the Major Direction.

Type #6

Places 2-D (both dimensions the same size) loop at the To end of the original element, first in the plane of the Major Direction and then in the plane of the Minor Direction.

Type # 7

Builds a loop of the same size as the original element.

Type # 8

Builds a 2-D (both dimensions the same size) loop of the same size as the original element, first in the Major Direction and then in the Minor Direction.

Type #9

Causes CAESAR II to try all eight loop types and find the most economically efficient solution based on total pipe length and number of bends.