Specifies the interpolation method used by the software. The curves in WRC Bulletin 107 cover typical applications of nozzles in vessels or piping; however, should any of the interpolation parameters, such as U, Beta, and so forth, fall outside the limits of the available curves, then CAESAR II uses the last curve value in the appropriate WRC table.