Nozzle Check Report - CAESAR II - Help

CAESAR II Users Guide

Language
Русский
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

Defines the appropriate force/moment limits on a specified nozzle.

Data for each load case reported is a result of calculation (and can also be viewed on a Local Restraints report). The Limits shown in the report are the values from the input. Similarly, the Comparison method also reflects the input setting. The loads shown are the loads on the nozzle for the indicated load cases. If any load exceeds its corresponding allowable load, then the entire line is shown in red (with an asterisk at the far right in the event the report is printed in black and white.)

The Resultant column reports the resultant forces and moments for the SRSS Comparison method, and the unity check value for the Unity Check method.