API-653 Settlement Evaluation - TANK - Help - Hexagon PPM

TANK Help

Language
English
Product
TANK
Subproduct
TANK
Search by Category
Help

The Settlement Checks report details the results of the computations made according to the rules of API-653 Appendix B. This report provides the maximum allowed out-of-plane deflection and a table showing the out-of-plane settlement at each of the measurement points.

This table also includes the settlement measurements, the optimum cosine curve through these measured points, the out-of-plane settlement, and the out-of-plane deflection.