Alters the convergence tolerance for the solution of the optimum cosine curve. This is necessary for API-653, Appendix B computations. If there are convergence problems with the current data set, the following steps should be taken:

  1. Review and verify the shell settlement input data.

  2. Adjust this convergence tolerance upward.

Increasing the convergence tolerance reduces the accuracy of the solution. Alternatively, increase the iteration limit.