Weld Connections

Each weld on the weld table contains an associated connection key that specifies its connection. You can use Connection A for welds to the pipe and Connection B for welds to the supporting steel.

You can add multiple welds to a single connection at different locations.

Weld Locations

Each connection has four predefined locations, 2, 4, 6, and 8, similar to cardinal points on a steel cross-section. The locations control the weld location in the Weld plane. You can also use the three offset rules to offset the weld from the predefined location.

Connection A locations

The following picture illustrates welds placed against the pipe based on the length of the Shoe with no Pipe attachment:

Illustration of Connection A Location - No Pipe Attachment

The following picture illustrates welds placed against the pipe based on the Length2 of the Shoe with Pipe attachment such as Repad, Clamp, and so on:

Illustration of Connection A Location - With Pipe Attachment

Connection B locations

The following picture illustrates welds placed at the bottom of the Shoe irrespective of whether Pipe attachments are present or not: