Stiffener Attributes - Intergraph Smart Reference Data Standard Database - Version 12.2 - Help - Hexagon PPM

Standard Database for Intergraph Smart Reference Data Hangers and Supports Help

Language
English
Product
Intergraph Smart Reference Data Standard Database
Search by Category
Help
Standard Database for Smart Reference Data Version
12.2

Attribute Name

Description

Implementation Details

IJUAhsStiffenerSup::StiffenerSupport

Specifies the part number or the part class of a stiffener part. The part must be a Plate SmartPart.

  • Stiffener is mandatory.

  • You must specify either a StiffenerPart or a StiffenerRule.

IJUAhsStiffenerSupRL::StiffenerSupportRule

Specifies a rule that returns the part number of the stiffener part

IJUAhsFrStiffQty::StiffenerQty

Specifies the quantity of bolts to include on for connecting the MemberNPart and MemberNBPart. Usually, use StiffenerQtyRl to calculate the quantity based on the SpanValue and StiffenerSpace.

IJUAhsFrStiffQtyRI::StiffenerQtyRI

Defines an HgrSupportRule. The hanger rule must exist in the catalog; it can be a rule name or a ProgID. To select the quantity directly using StiffenerQty, do not type any value for this property.

IJUAhsStiffOn2Sides::StiffenersOn2Sides

A codelist hs YesNo specifying if Stiffeners are on two sides or not.

hsYesNo

1 - Yes

1 - No

IJUAhsStiffenerSpace::StiffenerSpace

Specifies the distance between the Stiffeners. Stiffeners will be placed starting from section middle with StiffenerSpace and StiffenerQty. To determine the stiffener space using StiffenerSpaceRI, do not type any value for this property.

StiffenerSpace

IJUAhsStiffenerSpaceRI::StiffenerSpaceRI

Defines an HgrSupportRule that returns the shoe height. The hanger rule must exist in the catalog; it can be a rule name or a ProgID. To determine the stiffener space directly using StiffenerSpace, do not type any value for this property.