ICalculatedLoads - Intergraph Smart Electrical - Reference

SpelCalcInf

Language
English
Product
Intergraph Smart Electrical
Search by Category
Reference
Smart Electrical Version
2018 (8.0)

ICalculatedLoads

ICalculatedLoads


Holds a set of calculation results.

Public:

Properties:

Name

Description

ContinuousActive (see ICalculatedLoads: ContinuousActive (get)) (get)

Get the active value of the loads with continuous operation mode

ContinuousReactive (see ICalculatedLoads: ContinuousReactive (get)) (get)

Get the reactive value of the loads with continuous operation mode

IntermittentActive (see ICalculatedLoads: IntermittentActive (get)) (get)

Get the active value of loads with intermittent operation mode

IntermittentReactive (see ICalculatedLoads: IntermittentReactive (get)) (get)

Get the reactive value of loads with intermittent operation mode

PeakActive (see ICalculatedLoads: PeakActive (get)) (get)

Get the active value of all loads

PeakApparent (see ICalculatedLoads: PeakApparent (get)) (get)

Get the apparent value of all loads

PeakCurrent (see ICalculatedLoads: PeakCurrent (get)) (get)

Get the current value of all the loads

PeakPowerFactor (see ICalculatedLoads: PeakPowerFactor (get)) (get)

Get the power factor of all loads

PeakReactive (see ICalculatedLoads: PeakReactive (get)) (get)

Get the reactive value of all loads

PeakReactiveCorrection (see ICalculatedLoads: PeakReactiveCorrection (get)) (get)

Get the reactive power correction needed to comply with required bus power factor when all the loads are running.

RunActive (see ICalculatedLoads: RunActive (get)) (get)

Get the active value of the loads with continuous or intermittent operation mode

RunApparent (see ICalculatedLoads: RunApparent (get)) (get)

Get the apparent value of the loads with continuous or intermittent operation mode

RunCurrent (see ICalculatedLoads: RunCurrent (get)) (get)

Get the current value of loads with continuous or intermittent operation modes

RunPowerFactor (see ICalculatedLoads: RunPowerFactor (get)) (get)

Get the power factor of the loads with continuous or intermittent operation mode

RunReactive (see ICalculatedLoads: RunReactive (get)) (get)

Get the reactive value of the loads with continuous or intermittent operation mode

RunReactiveCorrection (see ICalculatedLoads: RunReactiveCorrection (get)) (get)

Get the reactive power correction needed to comply with required bus power factor when continuous and intermittent loads are running

SpareActive (see ICalculatedLoads: SpareActive (get)) (get)

Get the active value of loads with spare operation mode

SpareReactive (see ICalculatedLoads: SpareReactive (get)) (get)

Get the reactive value of loads with spare operation mode

StandbyActive (see ICalculatedLoads: StandbyActive (get)) (get)

Get the active value of loads with standby operation mode

StandbyReactive (see ICalculatedLoads: StandbyReactive (get)) (get)

Get the reactive value of loads with intermittent operation mode