Problem

During the loading of published data to a project, you could encounter error messages such as these:

  • The Relationship already exists.

  • Failed to process the TaggedItemGroup data: Commit has failed, Object cannot be created. The UID is not unique in this config.

  • The updating of the claimed item failed.

Solution

To resolve this issue, you can add a key to Server Manager, ProcessDataLoadSequentialAtProject. When this flag is set to true, the load operations for the project are restricted to use only one thread, thereby avoiding any multi-thread issues. The flag can be turned off once the load operation is complete.

  • This flag is applicable only for loading data into project scenarios (ICC2).

  • The flag does not affect the loading of documents at the plant level, only at the project level.

  • You must add the flag to the Server Manager settings; it is not available by default.