If you specify a Repeatabiltiy Return file in the FLS file or a –117 record in the Spoolgen OPT file, I-Data Integrator reads the generated file, consolidates it, and then creates two new intrinsic recordsets: Components_2 and Welds_2. Both recordsets are processed in the same way as intrinsic recordsets that are created from the Material Control, Welding, Spool Information, or Bending files.
You must use the ASCII repeat file option. Set Option Switch 109 Position 1 to 7 Intergraph Corporation. I-Data Integrator reads the option switch settings and does not attempt to read the Repeatability file unless this value is set.
Components_2 Recordset
The Components_2 table contains the following fields:
Field |
Description |
PIPELINE |
Indicates the pipeline reference. |
DRG |
Indicates the drawing number. |
PT-NO |
Indicates the Isogen-generated part number. |
UPN |
Specifies a unique part number. This is the same as PT-NO if unique part numbering is not used or set to the Isogen generated unique part number if it is (for example, 1.1, 1.2, 1.3, 2.1, and so on). |
NS |
Specifies the nominal size in the current bore units (as specified by Option Switch 41). |
RECORDTYPE |
Indicates the Isogen record type (for example, 100 for pipe, 130 for valve, and so on). |
CATEGORY |
Specifies the category: NONE, FAB, EREC, OFF. |
UCI |
Specifies the unique component identifier. |
X |
Indicates the component position. |
Y |
|
Z |
|
Seq |
Specifies the sequence number in the repeat file |
If unique component identifiers are not present in the input file (IDF or PCF), the software does not generate any component records.
Welds_2 Recordset
The Welds_2 table contains the following fields:
Field |
Description |
PIPELINE |
Indicates the pipeline reference. |
DRG |
Indicates the drawing number. |
WELD-NO |
Indicates the Isogen-generated part number. |
NS |
Specifies the nominal size in the current bore units (as specified by option switch 41). |
SKEY |
Indicates the Isogen SKEY (for example, WW, WS, and so on). |
START_CPT |
Identifies the unique component identifier for the component at the weld “start”. |
START_X |
Indicates the start component position for the weld. |
START_Y |
|
START_Z |
|
FINISH_CPT |
Specifies the unique component identifier for the component at the weld “finish”. |
FINISH_X |
Indicates the finish component position for the weld. |
FINISH_Y |
|
FINISH_Z |
The format of the repeat file is fixed. The presence of REPEATABILITY-RETURN or a –117 record in the FLS or OPT file, respectively, is sufficient to trigger I-Data Integrator to read the data.