The following attributes define the combined base plate data-driven assembly, and are used to form the Combined Base Plate support. For more information on how to use the attributes, see Part Specifications.
Name |
User Name |
Category |
On Property Page |
Read Only |
---|---|---|---|---|
BasePlateSupport |
Base Plate Support |
Standard |
No |
Yes |
BasePlateSupportRule |
Base Plate Rule |
Standard |
No |
Yes |
GuideSupport |
Guide Support |
Standard |
No |
Yes |
GuideSupportRule |
Guide Support Rule |
Standard |
No |
Yes |
StiffenerSupport |
Stiffener Support |
Standard |
No |
Yes |
StiffenerSupportRule |
Stiffener Rule |
Standard |
No |
Yes |
LimitStopSupport |
Limit Stop Support |
Standard |
No |
Yes |
LimitStopSupportRule |
Limit Stop Rule |
Standard |
No |
Yes |
Attribute Name |
Description |
Implementation Details |
---|---|---|
IJUAhsBasePlateSup:: |
Specifies the part number of a base plate support. |
Specify either Base Plate or Grout support. You must enter a value for BasePlateSupport or BasePlateSupportRule. |
IJUAhsGuideSup:: |
Specifies the part number of a guide support. |
Guide support is optional. If you do not require a guide, do not specify any values for either the GuideSupport or GuideSupportRule. |
IJUAhsStiffenerSup:: |
Specifies the part number of a stiffener support. |
Stiffener support is optional. If you do not require a stiffener, do not specify any values for either the StiffenerSupport or StiffenerSupportRule. |
IJUAhsLimitStopSup:: |
Specifies the part number of a limit stop support. |
Limit Stop support is optional. If you do not require a limit stop, do not specify any values for either the LimitStopSupport or LimitStopSupportRule. |
IJUAhsGroutThickness:: |
Specifies the grout thickness. The value overrides the existing grout part thickness. |