Configuration Attributes - Intergraph Smart Reference Data Standard Database - Version 12.3 - Help - Hexagon PPM

SDB for SRD Hangers and Supports Help 12.3

Language
English
Product
Intergraph Smart Reference Data Standard Database
Search by Category
Help
Smart 3D Version
13
Standard Database for Smart Reference Data Version
12.3

A Pipe to Pipe support uses the following configuration:

sdb-configuration attributes (pipe to pipe)

Attribute Name

Description

Implementation Details

IJUAhs_PipeToPipeOH1::
Overhang1

Specifies the Overhang 1 value for the support.

The following definitions are supported:

1 - Outside Edge of Pipe

2 - Center of Pipe

3 - Inside Edge of Pipe

4 - Middle of UBolt

Pipe to Pipe - Config Attributes - Overhang1

IJUAhs_PipeToPipeOH2::
Overhang2

Specifies the Overhang 2 value for the support.

The following definitions are supported:

1 - Outside Edge of Pipe

2 - Center of Pipe

3 - Inside Edge of Pipe

4 - Middle of UBolt

Pipe to Pipe - Config Attributes - Overhang1

IJUAhs_PipeAttQty1::
PipeAttQty1

IJUAhs_PipeAttQty2::
PipeAttQty2

Specifies the number of pipe attachments the software places on each pipe.

IJUAhs_PipeAttOff1::
PipeAttOffset1

IJUAhs_PipeAttOff2::
PipeAttOffset2

Specifies the offset value for the pipe attachment, if the pipe attachment exists.

1 - Measured from Center

If there are two pipe attachments, the software offsets the attachments in opposite directions.

IJUAhs_ShoeHeight::
ShoeHeight

Specifies the shoe height. The software measures shoe height for the first selected pipe.

1 - Bottom of Pipe

For orthogonal configuration, measure from the bottom of the lowest pipe.

IJUAhs_InsulOffset::
InsulOffset

Specifies the value for the insulation offset, if the insulation is available.

The default units are specified in the CustomInterface worksheet of the HS_S3DAssy workbook; otherwise, specify the units.

Example: 25, 25mm, 25in.

IJUAhs_InsulOffsetRl::
InsulOffsetRl

Specifies a hgrSupportRule that returns an insulation offset value.

The hanger rule must be the name of an existing rule in the catalog.

To specify the offset using InsulOffset, do not type any value for this property.

Examples:

Rule Name: Offset2ByPipeSize

Rule ProgID: HS_S3DRules.Offset2ByPipeSize

IJUAhs_InsulOffsetDef:: InsulOffsetDef

Specifies the position where the software measures the insulation.

1 - Measured from center

IJUAhs_InsulOffsetSel:: InsulOffsetSel

Specifies the attribute that selects the insulation offset.

The default InsulOffset attribute is used if you do not specify a value.

hsSelection:

1 - By Rule

2 - By Input

IJUAhs_InsulLength:: InsulLength

Specifies the length of the insulation.

The default units are specified in the CustomInterface worksheet of the HS_S3DAssy workbook; otherwise specify the units.

For example, 25, 25mm, 3in.

IJUAhs_InsulLengthRl:: InsulLengthRule

Specifies a hgrSupportRule that returns the insulation length value.

The hanger rule must be the name of an existing rule in the catalog.

To specify the offset using InsulLength, do not type any value for this property.

Examples:

Rule Name: Gap2ByPipeSize

Rule ProgID: HS_S3DRules.Gap2ByPipeSize

IJUAhs_InsulLengthSel:: InsulLengthSelection

Specifies the attribute that selects the insulation offset.

The default InsulOffset attribute is used if you do not specify a value.

hsSelection:

1 - By Rule

2 - By Input

Pipe to Pipe - Config Attributes - Insulation - Length & Offset