Material List - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls the content of the material list on a piping isometric drawing.

This options group is not available when you are viewing a Smart 3D cable tray isometric drawing style or Smart 3D HVAC isometric drawing style, such as Iso_Cabletray or Iso_HVAC, respectively.

Exclude Weight Data

Specifies whether to exclude weight data from the material list and Supplementary reports.

Select the check box to exclude the component weight data extraction. To extract component weight data and include it in the material list and supplementary reports, clear the check box. This is the default setting.

Defines:

Option Switch - N/A
I-Configure - S3D.MaterialList.ExcludeWeightData

User Component Quantity Attribute

Specifies the user component quantity.

Use the list to select a material attribute in which the component quantity for piping components other than pipe is stored.

Defines:

Option Switch - N/A
I-Configure - S3D.MaterialList.UserDefinedComponentQTY

Exclude Nuts

Specifies whether to exclude nut data from the material list.

To exclude nut data, select the check box. If the check box ix cleared, Isogen excludes nut data and includes it in the material list. This is the default setting.

You must also set nuts as To be reported. On the Occurrence tab of the Properties dialog box for an item, set the Reporting Requirements property to To be reported.

Exclude Washers

Specifies whether to exclude washer data from the material list.

To exclude the washer data, select the check box. If you clear the check box, Isogen extracts washer data and includes it in the material list. This is the default setting.

You must also set washers as To be reported in the model. On the Occurrence tab of the Properties dialog box for an item, set the Reporting Requirements property to To be reported.