Tracing Style - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Specifies where heat tracing is shown on the isometric drawing.

Click Show Collapse ICP to display a gallery of shapes, and then select the appropriate setting.

  • Alongside Duct uses the default to plot chain dotted tracing lines alongside the pipe only, with a gap of 1 mm.

  • Alongside Pipe uses the default to plot chain dotted tracing lines alongside the pipe only, with a gap of 1 mm.

  • None suppresses tracing indication.

  • Alongside Duct and Components plots chain dotted tracing lines alongside pipe and all components, both with a 1 mm gap.

  • Alongside Pipe and Components plots chain dotted tracing lines alongside pipe and all components, both with a 1 mm gap.

Defines:

Option Switch - 62, Pos 1
I-Configure - Drawing.Format.TracingStyle