Imperial Format - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls the format of imperial measurements on the isometric drawing.

  • Standard outputs measurements using the standard ft/in format: 6' 10.3/4".

  • Dash inserts a dash between the feet and inches: 6'-10.3/4".

  • Space Dash inserts a blank space instead of a period ( . ) between inches and fractions of an inch: 6'-10 3/4".

  • Stacked Dash outputs stacked fractions with a dash: 6'-10¾". This setting applies only to MicroStation .dgn output.

  • Stacked outputs stacked fractions without a dash: 6' 10¾". This setting applies only to MicroStation .dgn output.

  • 1DecimalPlace outputs decimal inches to one decimal place.

  • 2DecimalPlace outputs decimal inches to two decimal places.

  • 3DecimalPlace outputs decimal inches to three decimal places.

  • 4DecimalPlace outputs decimal inches to four decimal places.

Two additional setting are available for controlling the format of pipe dimensions:

  • Use inches only plots dimensions in inches only

  • Use feet and inches if above nn inches plots dimensions greater than the user-specified value (nn) in feet and inches.

Defines:

Option Switch - 41, Pos 3
I-Configure - Drawing.Dimensions.ImperialFormat