Re-import a pipeline - Intergraph Spoolgen - Help

Intergraph Spoolgen Help

Language
English
Product
Intergraph Spoolgen
Search by Category
Help
SmartPlant Foundation / SDx Version
10
I-Configure Version
6.0(2016)
Isogen Version
13.0(2016)
Smart Isometrics Version
7.2
Spoolgen Version
9.2

You usually use the Re-Import File command when one of the following situations exists:

  • There is an import failure because of the sheet splitting strategy in the import drawing style. For example, a very large piping data input file (IDF/PCF) cannot be sensibly fitted onto one drawing sheet. In this case, the original Isogen file is extracted from the project database and re-imported using settings that temporarily override the current SGImport style setting (for a legacy Spoolgen project) or the Import style setting (for a SpoolgenDB project) as defined in I-Configure.

  • You need to view the current state of the POD reflected on screen, such as after the insertion of a drawing split point. In this case, the current open POD is exported to a PCF and then re-imported. Using the Re-Import File dialog box, you can override the SGImport or Import style settings as defined in I-Configure.

  1. Click Project > Re-Import File to open the Re-Import File dialog box.

    SHARED Tip The Re-Import File command is available only when a file is open in the software.

  2. Specify the required action, and define the required settings.

  3. Click OK.

During the re-import process, the software saves the SGReImport.log file in the %TEMP% folder.