End Connection and End Position messages - Intergraph Spoolgen - Help

Intergraph Spoolgen Help

Language
English
Product
Intergraph Spoolgen
Search by Category
Help
SmartPlant Foundation / SDx Version
10
I-Configure Version
6.0(2016)
Isogen Version
13.0(2016)
Smart Isometrics Version
7.0(2019)
Spoolgen Version
9.0(2019)

You can add the following messages to show the condition at the end of a pipeline leg:

  • End-Connection-Pipe

  • End-Connection-Equipment

  • End-Position-Closed

  • End-Position-Open

  • End-Position-Null

  • End-Position-Vent

  • End-Position-Drain

End Connection/Position messages

Apart from the End-Connection-Pipe and End-Connection-Equipment messages, which require you to define an item-specific attribute, you place end connection and position messages using the following technique:

  1. On the Selection ribbon, use the Type list to select the type of end connection or end position message to place.

  2. In the Graphics window, select the point on the pipeline where the message is to display, and then click OK on the Selection ribbon.

    The software displays the associated short description (EPC) for an End-Position-Closed message.

End-Connection-Equipment and End-Connection-Pipe messages

  1. On the Selection ribbon, use, the Type list to select the type of end connection/position message to place.

    If you are placing an end-connection-equipment message, type the nozzle reference in the Connection Reference box.
    -OR-
    If you are placing an end-connection-pipeline message, type the pipeline reference in the Pipeline Reference box.

  2. In the Graphics window, select the point on the pipeline where the message is to display, and then click OK on the Selection ribbon.

    The software displays the short description that corresponds to the end connection / position type (ECE or ECP) and the associated connection or pipeline reference information.