In this module, you can load piping welds directly from a single file or load F files and L files as separate files.
-
Click SPG Welds.
-
Click Load Drawings to load only L files (drawing files). After the files are loaded, you can view the drawing numbers in the list.
-
Click Load Data to load L files and F files from a single Excel file.
-
Click Load SPG Data . The SELECT SPOOLGEN FILES box appears.
-
Click Browse across Upload F file to load the F files (Weld information files), select the required Excel file and click Open.
-
Click Browse across the Upload L file to load the L files (drawing related files), select the required Excel file and click Open.
The revision number in both F files and L files must be same.
-
Click Load.
-
In the search bar, enter *, select any filter criteria, and click Refresh .
The software displays all the ISO/Drawing Numbers that satisfy the filter criteria.
If you want particular drawing numbers to be displayed in the ISO/Drawing No list:
-
Copy the ISO/Drawing numbers from the Excel sheet and paste them in the Search bar. After you paste the drawing numbers in the Search bar, they are separated with the | symbol.
For example, If you copy two drawing numbers from the Excel sheet and paste them in the Search bar, the drawing numbers appear as as HXN81X-S91011-IS030015|HXN81X-S91011-IS030016 separated with the | symbol.
-
In the Search bar, type the ISO/Drawing number in the format below:
*last two digits of the drawing number* or *Drawing number pattern*
For example, if the drawing number is HXN81X-S91011-IS030015, in the Search bar, type *15* or type *S91011*. Then only the drawing numbers related to the pattern will be displayed in the ISO/Drawing No list.
This is applicable to all the modules of Weld Quality Management System where ever there is a filter criteria for ISO/Drawing numbers.
-
-
Select an ISO from the list, and all the welds on that ISO are displayed in the table.
-
Select the welds and click Generate Weld Cardto generate a report for the weld data.