After installing Smart Review on a XenDesktop server, you must edit the SPRDisplaySettings.ini file delivered with Smart Review based on your video hardware. You can use any standard text editor.

NVidia K2 Grid Card

Follow the steps below to edit the contents of the [ViewSettings] section if you are using an NVidia K2 Grid card for graphics acceleration.

Before you begin, we recommend that you make a backup copy of the SPRDisplaySettings.ini delivered with Smart Review.

  1. Locate and open SPRDisplaySettings.ini.

  2. Under [ViewSettings], replace:

    VBOMemoryPercent=100

    with

    VBOMemoryPercent=10000

  3. Add the line:

    MaxTessellatorCount=1

  4. Save the file.

Server CPU

Perform the following steps if you are using the Citrix CPU server for video rendering.

  1. Locate and open SPRDisplaySettings.ini.

  2. Under [ViewSettings], add the line:

    MaxTessellatorCount=2

  3. Save the file.