Go to CMS > CMS Component Manager.
-
Expand SDB_ENTERPRISE CONTENT and navigate to INSTRUMENTS > FLOW SWITCH CUSTOM class.
-
Right-click the class and select Manage properties > Assign Properties.
-
Attributes assigned to Parent Classes are displayed.
-
Right-click and delete these attributes.
-
Click Save grid and then click Read-only grid to set the grid to read-only mode.
-
Select CMS Class Properties tab.
-
Select Edit grid in the Assign Properties window.
-
Click the Add Row button.
-
Open the FlowSwitch part class sheet from the excel workbook exported in section Stock Instruments.
-
Select all the part properties as shown below and then select Ctrl+C to copy the attributes.
-
Go back to the Assign Properties window and select Paste (Transpose*) from the right mouse click menu.
-
Select Attribute in the below prompt.
-
Delete the empty row1 from the grid.
-
Copy the attributes from Attribute column into Smart 3D Attribute column.
-
Click Save grid and then click Read-only grid to set the grid to read-only mode.