Create Piping Material Class Data. (PMCD sheet – Spec Header info) - Intergraph Smart Reference Data - Version 10.1 - Training - Hexagon

Intergraph Smart Reference Data Training (10.1)

Language
English
Product
Intergraph Smart Reference Data
Search by Category
Training
Smart Materials/Smart Reference Data Version
10.1
  1. Click Open for Edit button in the Grid view tool bar.

    Create Piping Material Class Data

  2. Scroll down to Add Spec Header Geometric entries as shown below and save the changes.

    Create Piping Material Class Data 2

    Create Piping Material Class Data 3

    • Spec header geometrics are used to create idents based on the specification. Idents are created only for the size ranges defined in the Spec Items.

    • To select a Unit System, Short Code etc. click the button next to the corresponding option.

    • To add multiple rows, press the down arrow key or right click on the row and select Add Row option.

  3. Click the down arrow key to Add Specification Details entries as shown below and save the changes.

    PMCD Sheet - Spec Header Info - Specification Details

    PMCD Sheet - Spec Header Info Specification Details - 2

  4. Click Save button.

  5. Click the Temperature/Pressure icon to assign the P/T Table.

    Create Piping Material Class Data 6

  6. Click New Add icon and then click Assign button to select the P/T table “PT_10CA01B1” from the LOV.

    PMCD sheet - Spec Header info - image 3

  7. Double click the Rating Geometric PT_10CA01B1. System will prompt if you want to Use Existing table or Copy Geom Code.

  8. Click the Use Existing button.

    • If you select Use Existing option and then make any changes to the geometric, then those changes will be saved in the selected geometric. This change gets reflected in all the specs in which this geometric is selected.

    • If you select Copy Geom Code then the system will create a copy of the selected rating geometric. Hence, the changes made to this geometric will not affect the original selected geometric.

    Create Piping Material Class Data 8

    Create Piping Material Class Data 9

  9. Click Save button.

  10. Click the Notes icon and add a header note using List of Values, as shown below.

    Create Piping Material Class Data 10

  11. Click Save and click Read-only Grid .