You can manage general configuration item values.

  1. Click Integration > PDMS > PDMS Transfer Jobs.

  2. Click the General Configurations tab.

  3. Double-click a general configuration in the tree view.

  4. In the PDMS General Configuration Item Values grid, click Edit Grid EditGrid.

  5. Click Add Row PropertiesNew, and select a general configuration item from the Selection list LOV.

  6. Type a description for the item in the Item Comment cell, and select a value from the Selection list LOV in the Value cell.

  7. Click Save Grid SaveGrid, and then click Read-Only Grid ReadOnly.

Set the AUTO_FILTER_VALVEOP_CLASS_SHTS_IN_SPEC configuration to Y to filter the valve operator part class data tables.

Following are the list of general configurations that you must select for the Ident or Specification transfer files:

File Name

General Configuration

Value

C.DAT

  • ATTRIBUTE_FOR_DRYWEIGHT

  • CMPW_SUFFIX

Is picked from the Geometrics page

F.DAT

  • ATTRIBUTE_FOR_BLT_DIA

  • ATTRIBUTE_FOR_BLT_NUMB

  • ATTRIBUTE_FOR_BLT_THKNESS

For all the Flange Components, you must define the Bolt Commodity Codes in the Spec Item grid page.

BS.DAT

  • ATTRIBUTE_FOR_NUTS

  • ATTRIBUTE_FOR_STUDNUTS

  • ATTRIBUTE_FOR_WASHER

M.DAT

  • NLS_RTEXT_XTEXT

  • NLS_STEXT_YTEXT

  • NLS_TTEXT_ZTEXT

  • MATXT_TABLE_NAME

B.DAT

No specific configurations

G.DAT