A. Creating a New Specification
FILE NAME: e.g. new_b511_12345.spec
NEW SPECIFICATION /B511
LINETYPE NULL
TEXT 'PIPING'
HEADING
TYPE NAME PBOR1 PBOR2 STYP SHOP CATREF DETAIL MATXT CMPREF BLTREF
DEFAULTS
- - - - = =
FLAN */AAFSBF0DD 15.00 15.00 TEXT 'FLSW1' TRUE /AAFSBF0DD /6497796-D /S54U_502950-M /6497796-C =0
EXTRA :TP-IDENT 'C5FN5D'
EXTRA :TP-COMMCODE 'FSW1S54U22D01'
FLAN */AAFSBF0EE 20.00 20.00 TEXT 'FLSW1' TRUE /AAFSBF0EE /6397957-D /C54X_502950-M /6397957-C =0
EXTRA :TP-IDENT 'C5CWFZ'
EXTRA :TP-COMMCODE 'FSW1C54X22D01'
B. Creating a New Component in an Existing Specification
FILE NAME: e.g. insert_b511_12345.spec
OLD SPECIFICATION /B511
HEADING
TYPE NAME PBOR1 PBOR2 STYP SHOP CATREF DETAIL MATXT CMPREF BLTREF
DEFAULTS
- - - - = =
FLAN */AAFSBF0FF 25.00 25.00 TEXT 'FLSW1' TRUE /AAFSBF0FF /6397958-D /C54X_502950-M /6397958-C =0
EXTRA :TP-IDENT 'C5CWG0'
EXTRA :TP-COMMCODE 'FSW1C54X22D01'
FLAN */AAFSBF0HH 40.00 40.00 TEXT 'FLSW1' TRUE /AAFSBF0HH /6397959-D /C54X_502950-M /6397959-C =0
EXTRA :TP-IDENT 'C5CWG1'
EXTRA :TP-COMMCODE 'FSW1C54X22D01'
The same format is used as defined in case A.
C. Modifying a Component in a Specification
Reference is made to case A and B, which are supposed to be loaded before C.
FILE NAME: e.g. modify_b511_12345.spec
OLD SPECIFICATION /B511
HEADING
NAME TYPE PBOR1 PBOR2 STYP SHOP CATREF DETAIL MATXT CMPREF BLTREF
DEFAULTS
- - - - = =
*/AAFSBF0DD FLAN 15.00 15.00 TEXT 'FLSW1' TRUE /AAFSBF0DD /15858200-D /S54U_502950-M /6497796-C =0
EXTRA :TP-IDENT 'C5FN5D'
EXTRA :TP-COMMCODE 'FSW1S54U22D01'
*/AAFSBF0EE FLAN 20.00 20.00 TEXT 'FLSW1' TRUE /AAFSBF0EE /632500007-D /C54X_502950-M /6397957-C =0
EXTRA :TP-IDENT 'C5CWFZ'
EXTRA :TP-COMMCODE 'FSW1C54X22D01'
*/AAFSBF0FF FLAN 25.00 25.00 TEXT 'FLSW1' TRUE /AAFSBF0FF /63002456-D /C54X_502950-M /6397958-C =0
EXTRA :TP-IDENT 'C5CWG0'
EXTRA :TP-COMMCODE 'FSW1C54X22D01'
*/AAFSBF0HH FLAN 40.00 40.00 TEXT 'FLSW1' TRUE /AAFSBF0HH /6397959-D /C54X_502950-M /22200-C =0
EXTRA :TP-IDENT 'C5CWG1'
EXTRA :TP-COMMCODE 'FSW1C54X22D01'
In this case, columns NAME and TYPE shall be swapped.
In this example, 15858200-D replaces /6497796-D in case A.
D. Removing a Component
Reference is made to cases A, B, and C, which are supposed to be loaded before D.
FILE NAME: e.g. delete_b511_12345.spec
OLD SPECIFICATION /B511
REMOVE */AAFSBF0DD
REMOVE */AAFSBF0EE
REMOVE */AAFSBF0FF
This format is necessary to remove components that are no longer needed from the spec. Old information will be switched from an active spec to a hold spec named LIMBO by PDMS.
No header is needed to proceed.
The spec header contains:
DESC ‘Revision date …..’
This is controlled by a CIP.