  1. Open the S.50.06 Specification Management screen.

  2. Select the 1CA1S01 specification (or your copy of this specification).

  3. Double-click in the Spec Code box to open Window 2.

  4. Click New record (or press F6) to add a new row.

  5. Type 900 in the Seq box, select SGL from the LOV in the Short Code box, select MP from the LOV in the Group box, select SG from the LOV in the Part box, select 1 from the LOV in the Option box, and select the commodity code displayed in the picture below from the LOV in the Commodity Code box.

  6. Type .75 in the From 1 box and 8 in the To 1 box.

  7. Click Go to next block to open Window 3.

  8. Click Build Idents to build the idents for the selected specification item.

  9. Click Go to next block to open Window 2.

    The specification is now ready to export.