The following section shows how to create a component using the example of a manufacturer-specific ball valve with a lever operator as a special component.
Component description
Ball valve (VCK-41) / #150 (AH-35) / Raised Face End (AB-21) / ANSI-B16.34 (AAT-64) / Lever operator (IQ-10305), Dimension Face to Face acc. to ASME B16.10-1986 (Long Pattern Dim. A - page 7) / Dry Weight and Valve Height acc. to Velan (VEL-BV-93 page15-Full Port)
Dimensional data
Nom Size 1 |
Unit |
Nom Size 2 |
Unit |
FtF |
Height |
Dry Weight |
---|---|---|---|---|---|---|
0.5 |
in |
0.5 |
in |
4.25in |
3.49in |
4.4lbm |
0.75 |
in |
0.75 |
in |
4.62in |
4.09in |
6.6lbm |
1 |
in |
1 |
in |
5in |
4.21in |
8lbm |
1.25 |
in |
1.25 |
in |
5.5in |
4.5in |
12lbm |
1.5 |
in |
1.5 |
in |
6.5in |
4.85in |
14.9lbm |
2 |
in |
2 |
in |
7in |
5.44in |
24lbm |
2.5 |
in |
2.5 |
in |
7.5in |
6.97in |
44lbm |
3 |
in |
3 |
in |
8in |
7.38in |
52lbm |
4 |
in |
4 |
in |
9in |
10.33in |
90lbm |
6 |
in |
6 |
in |
15.5in |
12.56in |
196lbm |
8 |
in |
8 |
in |
18in |
13.06in |
420lbm |
10 |
in |
10 |
in |
21in |
18.84in |
762lbm |
These ball valves can have different operator types.
Example (SymbolDefinition) = Operator10005.COperator10005
Operator Type 10005
0.5 - 1.25in |
Operator Height = Valve Height + 0.525in |
OpDim1 = 1.5in |
1.5 - 3in |
Operator Height = Valve Height + 0.7in |
OpDim1 = 2in |
4 - 6in |
Operator Height = Valve Height + 1.05in |
OpDim1 = 3in |
8in - 10in |
Operator Height = Valve Height + 1.4in |
OpDim1 = 4in |