The definition of the ball valve itself is complete, and now the operator must be configured.

Operator Type 10005 is needed, with SymbolDefinition Operator10005.COperator10005.

0.5 - 1.25in

Operator Height = Valve Height + 0.525in

OpDim1 = 1.5in

1.5 - 3in

Operator Height = Valve Height + 0.7in

OpDim1 = 2in

4 - 6in

Operator Height = Valve Height + 1.05in

OpDim1 = 3in

8in - 10in

Operator Height = Valve Height + 1.4in

OpDim1 = 4in

For the operator definition, these following sheets are needed and must be defined or updated:

Operator10005

PipingCommodityMatlControlData

ValveOperatorMatlControlData