Add revision number attribute to Piping Material Class Data sheet - Intergraph Smart Reference Data - Version 10.1 - Customization & Programming - Hexagon

Intergraph Smart Reference Data Integration (10.1)

Language
English
Product
Intergraph Smart Reference Data
Search by Category
Customization & Programming
Smart Materials/Smart Reference Data Version
10.1

This procedure uses the PipingCommodityFilter sheet as an example. The same configuration is required for all other PMC sheets listed below.

  1. Go to Integration > Smart 3D > Smart 3D Configuration > Data Table Configurations screen, select the PipingCommodityFilter sheet assigned to a data table configuration.

  2. Double click the PipingCommodityFilter and go to the Attributes tab, create a new record.

  3. Select RevisionNumber from the LOV in the Attribute Name column.

  4. Select BASE_COLUMN from the Retrieval Method drop-down list.

  5. Type m_pck_spec_rev.spec_revision_number(sh.spec_header_id) in the Source box.

  6. Type 1 in the Unique Key box.

  7. Click Save.

    add_revision_number

Pipe Material Class Sheets

  • PipingCommodityFilter

  • PipingMaterialsClassData

The RevisionNumber attribute already exists for PipingMaterialsClassData. Move it to the second position after SpecName.

  • ServiceLimits

  • PipeNominalDiameters

  • PipeBranch

  • PermissibleTaps

  • JointQualityFactor

  • ThicknessDataRule

  • ReinforcingPadData

  • ReinforcingWeldData

  • BoltSelectionFilter

  • NutSelectionFilter

  • WasherSelectionFilter

  • GasketSelectionFilter

  • ClampSelectionFilter

  • AllowablePipingMaterialsClass

  • BendAngles

  • CorrosionAllowance

  • DefaultProjectOptions

  • InsideSurfaceTreatment

  • OutsideSurfaceTreatment

  • MinimumPipeLengthRulePerSpec

  • MinPipeLengthPurchasePerSpec

  • PipeTakedownParts

  • PortAlignmentPerSpec