This procedure uses the PipingCommodityFilter sheet as an example. The same configuration is required for all other PMC sheets listed below.
-
Go to Integration > Smart 3D > Smart 3D Configuration > Data Table Configurations screen, select the PipingCommodityFilter sheet assigned to a data table configuration.
-
Double click the PipingCommodityFilter and go to the Attributes tab, create a new record.
-
Select RevisionNumber from the LOV in the Attribute Name column.
-
Select BASE_COLUMN from the Retrieval Method drop-down list.
-
Type m_pck_spec_rev.spec_revision_number(sh.spec_header_id) in the Source box.
-
Type 1 in the Unique Key box.
-
Click Save.
Pipe Material Class Sheets
-
PipingCommodityFilter
-
PipingMaterialsClassData
The RevisionNumber attribute already exists for PipingMaterialsClassData. Move it to the second position after SpecName.
-
ServiceLimits
-
PipeNominalDiameters
-
PipeBranch
-
PermissibleTaps
-
JointQualityFactor
-
ThicknessDataRule
-
ReinforcingPadData
-
ReinforcingWeldData
-
BoltSelectionFilter
-
NutSelectionFilter
-
WasherSelectionFilter
-
GasketSelectionFilter
-
ClampSelectionFilter
-
AllowablePipingMaterialsClass
-
BendAngles
-
CorrosionAllowance
-
DefaultProjectOptions
-
InsideSurfaceTreatment
-
OutsideSurfaceTreatment
-
MinimumPipeLengthRulePerSpec
-
MinPipeLengthPurchasePerSpec
-
PipeTakedownParts
-
PortAlignmentPerSpec