Build Spec Idents - Intergraph Smart Reference Data - Help - Hexagon

Intergraph Smart Reference Data Help (10.1)

Language
English
Product
Intergraph Smart Reference Data
Search by Category
Help
Smart Materials/Smart Reference Data Version
10.1

With Build Spec Idents button you can build idents for a selected specification using Spec Header Geometrics or Common Spec Header Geometrics.

Several parameters such as Project Default value, Create Idents checkbox, Filter checkbox, Table Type, attributes in Object Parameter, Geometrics that have Size and Schedule data etc. are considered while building idents for a specification.

We can build idents for all the components and the following table lists some of the cases. These cases are explained by considering Reducer component because it has the maximum parameters (Size1, Size 2, Schedule1, and Schedule2).

Project Default ZS_CSHGAUT: This project default specifies whether to consider Common Spec Header Geometrics (CSHGs) for building idents if no matching geometrics are found in Spec Header Geometrics.

  • Module(s) affected by this setting: Spec Editor

  • Default value: N

  • List of Values: N/Y

Cases for Specification Header Geometrics

Case

Details

Case 1

Parameters

  • ZS_CSHGAUT = N

  • Object Parameters = Size A, Size B, Schedule A, Schedule B

  • Table Type = User Defined or Branches

  • Size and Schedule ranges = Available

  • Sizes and Schedules = Available in Geometric Table-1

  • Create Idents checkbox for Geometric Table-1 = Selected

Q: Are the idents built?

A: Yes, the idents are built.

From the above parameters, system builds idents by considering both Size and Schedule details from Spec Header Geometric grid.

Case 2

Parameters

  • ZS_CSHGAUT = N

  • Object Parameters = Size A, Size B, Schedule A, Schedule B

  • Table Type = User Defined or Branches

  • Size and Schedule ranges = Available

  • Sizes and Schedules = Sizes in Geometric Table-1; Schedules in Geometric Table-2

  • Create Idents checkbox for Geometric Table-1 and Geometric Table-2 = Selected

  • Filter checkbox for Geometric Table-2 = Selected

Q: Are the idents built?

A: Yes, the idents are built.

From the above parameters, system builds idents by considering Size details from Geometric Table-1 and Schedule details from Geometric Table-2 available in Spec Header Geometric grid.

Cases for Common Specification Header Geometrics

Case

Details

Case 1

Parameters

  • ZS_CSHGAUT = Y

  • Object Parameters = Size A, Size B, Schedule A, Schedule B

  • Table Type = User Defined or Branches

  • Size and Schedule ranges = Available

  • Sizes and Schedules = Available in Geometric Table-1 from Spec Header Geometric grid

  • Create Idents checkbox for Geometric Table-1 = Selected

Q: Are the idents built?

A: Yes, the idents are built.

From the above parameters, system builds idents by considering both Size and Schedule details from Spec Header Geometric grid.

Case 2

Parameters

  • ZS_CSHGAUT = Y

  • Object Parameters = Size A, Size B, Schedule A, Schedule B

  • Table Type = User Defined or Branches

  • Size and Schedule ranges = Available

  • Sizes and Schedules = Available in Geometric Table-1 from Common Spec Header Geometric grid

  • Create Idents checkbox for Geometric Table-1 = Selected

Q: Are the idents built?

A: Yes, the idents are built.

From the above parameters, system builds idents by considering both Size and Schedule details from Common Spec Header Geometric grid.

Case 3

Parameters

  • ZS_CSHGAUT = Y

  • Object Parameters = Size A, Size B, Schedule A, Schedule B

  • Table Type = User Defined or Branches

  • Size and Schedule ranges = Available

  • Sizes and Schedules = Schedules available in Geometric Table-1 from Spec Header Geometric grid; Sizes available in Geometric Table-2 from Common Spec Header Geometric grid

  • Create Idents checkbox for Geometric Table-1 and Geometric Table-2 = Selected

  • Filter checkbox for Geometric Table-2 = Selected

Q: Are the idents built?

A: Yes, the idents are built.

From the above parameters, system builds idents by considering Schedule details from Geometric Table-1 available in Spec Header Geometric grid and Size details from Geometric Table-2 available in Common Spec Header Geometric grid.

Case 4

Parameters

  • ZS_CSHGAUT = Y

  • Object Parameters = Size A, Size B, Schedule A, Schedule B

  • Table Type = User Defined or Branches

  • Size and Schedule ranges = Available

  • Sizes and Schedules = Available in Geometric Table-1 from Spec Header Geometric grid and Geometric Table-2 in Common Spec Header Geometric grid

  • Create Idents checkbox for Geometric Table-1 and Geometric Table-2 = Selected

Q: Are the idents built?

A: Yes, the idents are built.

From the above parameters, system builds idents by considering both Size and Schedule details from Geometric Table-1 available in Spec Header Geometric grid.

If geometrics are available in both Spec Header Geometrics and Common Specification Header Geometrics, then the system always considers geometrics from Specification Header Geometrics grid.