You must make the following changes in the Data Dictionary Manager.
-
Copy the INI file ActuatorTypeAndSymbolName.ini under the folder specified in Options Manager Settings parameter Catalog Explorer Root Path.
-
If the file is not copied, default symbol files will be used, which is hard coded.
-
Set the active plant as desired via Drawing Manager.
-
Open the Data Dictionary Manager and edit the database tables as follows:
-
Select the Database Table for Inline Component.
-
Highlight the Actuator Type property, right click and select Properties. Add the value SmartInstrValveProgram.ValidationFunc to the Validation ID field as follows:
-
Click OK.
-
Select the Database Item Type for Instrument.
-
In the Validation Program field, replace PlantItemValidation.Validate with SmartInstrValveProgram.ValidationFunc as follows:
-
Click OK.
-
-
Click Save and exit Data Dictionary Manager.