  1. Open a drawing.

  2. Double-click an inconsistency indicator. Or you can right-click an inconsistency indicator to review its properties.

  3. On the Consistency Check Dialog, select the inconsistency that you want to correct in the list.

  4. Chose the appropriate solution from the Solutions list. The options in the Solutions list vary, depending on the type of inconsistency.

    An example of a solution is Copy property value Item 1 => Item 2, which could involve inconsistent nominal diameters of a pipe and nozzle, for example. If you determine that this solution is the best one, you can select it and select Apply. Or you can use the Properties window to change the nominal diameter of either the pipe or nozzle. Changing the diameter confirms that the values are consistent with the information that exists in Rule Manager.

  5. Select Apply.

  • Consistency Check identifies the type of problem with these symbols:

PPM All Outputs Graphic

Errors

PPM All Outputs Graphic

Warnings

PPM All Outputs Graphic

Approved warnings

  • A Drawing view also offers graphical symbols to alert you to possible problems:

PPM All Outputs Graphic

Warning for suspicious construction in the Drawing view

PPM All Outputs Graphic

Error in the Drawing view that warrants your inspection and correction