Specification Items - Intergraph Smart Materials - Version 2020 (10.0) - Training - Hexagon

Intergraph Smart Materials Classic Lab Tutorials (2020)

Language
English
Product
Intergraph Smart Materials
Subproduct
Classic
Search by Category
Training
Smart Materials/Smart Reference Data Version
2020 (10.0)

Purpose

This section explains how to create specification items.

Exercise

  1. Open the S.50.06 Specification Items screen from Smart Reference Data > S.50 Specification. The screen usually opens in enter query mode, and all fields are empty and are displayed with a yellow background. If not, click the Enter Query button to change to query mode.

  2. Enter the previously created specification code (TRAIN_1CS150) in the Spec Code field or open the LOV using the List of Values button and select the spec code from the list. Then click OK to close the LOV.

  3. Click the Run Query button to display the selected specification with its details.

  4. Double-click on the Spec Code field to open Window 2 of S.50.06.

  5. Click in the Short Code field of the first record.

  6. Open the LOV using the List of Values button, and select the short code ā€˜PIPā€™ from the list. Then click OK. The selected value will be entered in the Short Code field and the LOV is closed.

  7. Open the LOV in the Group field using the List of Values button, and select the group ā€˜Pā€™ from the list. Then click OK. The selected value will be entered in the Group field and the LOV is closed.

  8. Open the LOV in the Part field using the List of Values button, and select the part ā€˜PPā€™ from the list. Then click OK. The selected value will be entered in the Part field and the LOV is closed.

    The Option field was filled automatically with Option 1 by default, and we will keep this value.

  9. Move to the Commodity Code field, open the LOV using the List of Values button, click the button, and select the commodity code PPPABQBEACRAAG from the list. Then click OK. The selected value will be entered in the Commodity Code field and the LOV is closed.

  10. Enter the values .5 in the From1 field and 2 in the To1 field, or use the LOV on both fields and select the values from the list.

  11. Next, move to the Unit1 field and select the unit in. from the LOV.

  12. If a geometric was filled automatically into the Geom1 field, delete this value. Be sure that the Geom1 field is empty before saving.

  13. Save the changes using the Save button.

  14. Close the screen by selecting File > Close All from the main menu.