The following error messages can be issued by Smart Materials on the S.80.11 – OII Import Jobs screen.

MAR-15800

Cause:

Action:

No import file specified

You tried to start an import job without specifying an import file.

Specify a valid import file.

MAR-15801

Cause:

Action:

Setting 'OII_IMPORT_PATH' not defined

You tried to use the default directory setting, but it is not defined on A.60.04 or A.20.12/13.

Define the setting on A.60.04 DBA Settings, on A.20.12 Project Defaults, or on A.20.13 Project/Discipline Defaults.

MAR-15802

Cause:

Action:

No job code specified

You attempted to submit an import job without specifying a valid job code.

Specify a valid job code and commit the job definition.

MAR-15803

Cause:

Action:

Please commit your changes first

You attempted to start a job without committing the definition.

Commit the job definition.

MAR-15804

Cause:

Action:

Please enter a complete job definition first

You failed to supply all job details that are mandatory.

Supply all information that is needed.

MAR-15805

Cause:

Action:

Import job finished with return status #1

The online job execution finished. (This is not necessarily an error message)

Depending on the outcome of the job execution, you may proceed with reviewing the import protocol. If the return status is 'ERROR', more information about the kind of error will be given in the info panel on the S.80.11screen.

MAR-15806

Cause:

Action:

OII-SQL*Loader: #1

SQL*Loader failed to finish the first step (importing the file into the interface table) successfully. This error may merely be a file access error, or it could be related to the import data itself. Please review the SQL*Loader log file, bad file, and discard file.

The necessary action depends on the exact cause of the error. If, for example, you simply specified a non-existent file, then you could create a new job definition with a valid file and start over.

MAR-15807

Cause:

Action:

Could not lock OII Job table exclusively

This error indicates that another concurrent OII import job is running, or another pending transaction against the job definition table exists, holding a lock.

For the reasons outlined in Job Execution, the Open Ident Interface is not multi user-enabled. Retry the operation when the other job has finished.

MAR-15810

Cause:

Action:

#1 records of import data for this job have been deleted

On the S.80.11 screen, you are given the option of deleting all interface table data for a specific import job in order to free that database space. This message tells you how many records in the interface table been deleted. This message is only an informational message.

No action is required. Please note that deleting the interface data records will not affect the ident data or assembly data that has been imported by this job. It will only delete the imported ASCII file from the interface table, and after doing so, you will not be able to see the import record that is related to specific protocol messages on S.80.11. You should only perform this operation if you do not need any online access to the protocol details anymore.

MAR-15811

Cause:

Action:

Call to #1 raised SQL error #2

This error is an internal error message not normally issued.

Please make sure to record all details, especially all accompanying SQL error messages that are displayed or appear in the log file, and then contact Smart Materials Support.

MAR-15812

Cause:

Action:

Setting 'SQLLDR_EXECUTABLE' not defined

You attempted to start an online import; however, the necessary setting on A.60.04 that tells Smart Materials how Oracle SQL*Loader must be called is not configured.

Configure this setting on A.60.04, and start over with a new import job definition.

MAR-15813

Cause:

Action:

OII Online import aborted due to fatal error

A fatal error occurred that made further execution of the import job impossible. This error message may be accompanied by Smart Materials error message MAR-15811 or MAR-15808. In case of an internal error, it may be accompanied by an Oracle error message from the database server.

If the accompanying messages in the info panel or in the log file do not reveal the exact cause of this error, or if they do, but you are not sure about how you could avoid the circumstances under which this error occurs, you should contact Smart Materials Support. Please be sure to record all details, especially all accompanying SQL error messages that are displayed or appear in the log file.

MAR-15814

Cause:

Action:

Setting 'PLUS_EXECUTABLE' not defined

You attempted to start an online import; however, the necessary setting on A.60.04 that tells Smart Materials how the ORACLE SQL*Plus program must be called is not configured (SQL*Plus is needed to generate the import protocol file).

Configure this setting on A.60.04, and start over with a new import job definition.

MAR-15815

Cause:

Action:

File I/O Error #1

On the S.80.11 screen, you attempted to view the log file that was created for an online import job. However, for some reason that is detailed by this error message, access to the server file system failed.

Contact your DBA, Smart Materials administrator, or database server system administrator to have one of them check why file access is not possible. One reason may be that your Smart Materials installation is configured to store Smart Materials log files in a temporary directory that will be deleted by a background job at regular intervals.