This project default controls whether branch break logic is applied during the FIND_IDENT BOM check or not.

If set to Y, for branch materials that do have a header/branch size combination with break type UPPER in their branch table (S.40.05), the FIND_IDENT check searches for the next higher header/branch size combination with break type STANDARD. If such a combination and an ident for it can be found, a new sub position on the BOM is created.

  • Module(s) affected by this setting: B2001, B200141, B2003

  • Default value: N

  • List of Values: N/Y