This project default controls the project session lock timeout value for OMI job execution when running online. The value is specified in seconds; the value -1 means that the B.40.01 screen does not wait at all; that is, when it detects that another import job for the same project is currently running, it will time out immediately; for other values, it will wait for the specified number of seconds. This mechanism is necessary to serialize jobs that import BOM data into the same project.
-
Module(s) affected by this setting: B4001
-
Default value: ./.
-
List of Values: -1, 10 - 1500 (increment 10)