Mapping Template File Contents - Intergraph Smart Interop Publisher - Help

Intergraph Smart Interop Publisher Help

Language
English
Product
Intergraph Smart Interop Publisher
Search by Category
Help
Smart Interop Publisher Version
16.2

The template files contain the following sheets:

ClassMap sheet

Lists the mapping between any new source object classes and the target object classes. Also lists UIDs for data objects contained in the classes. The UID values apply only to Smart Models being published to SmartPlant Foundation.

PropertyMap sheet

Lists the mapping between the source object properties and the target object properties. You can add new property mappings, or override the default mappings.

SPFSIOCodelistMapping

Supports codelist number mapping for Smart 3D and PDS source files.

PipingPortEndConnectionTable

Provides codelist number mapping for Smart 3D port property display from PDMS source files.

Source Class

Specifies the top-level grouping to which objects from your particular source belong.

Source Property

Specifies properties of all the objects in your data model.

Source Interface

Specifies collections of properties for objects in your data model. A source interface is basically a container of related properties. Most third-party authoring tools and legacy PDS data do not implement or have the concept of source interfaces, so this column is optional.

Target Class

Specifies the top-level grouping in Smart Interop Publisher into which source objects correspond.

Target Interface

Specifies a collection of object properties that are role-based. For Intergraph target applications, an interface is a role made up of properties that describe that role. For example, properties that define piping insulation such as thickness, purpose, and material are placed in an Insulation interface.

Target Property

Specifies the property labels for the objects as they display in the target applications.

Units

Specifies the working units of measure to use for the translation. The software reads the units only from the Units G column. You can set up the required properties to show metric or English string values.

When entering the units of measure for models being translated and published to SmartPlant Foundation, you must type the format as specified in SmartPlant Foundation. See Units of Measure Entries.