This option enables you to generate an actual load report per channel for a selected equipment card. This report includes the sum of all field device panels connected to a specific channel.

  1. In the Wiring Module window, select Reports > Telecom > Actual Load Report.

  2. On the Panel - Strip Selection dialog, select Find.

  3. Select a card and select Print.

  4. On the Print Preview Request, select Yes to display the report before printing it or select No to print out the report without displaying it first.

You can also generate this report from the Domain Explorer. Expand the hierarchy of a PA panel. Then, after right-clicking an amplifier, select Reports > Actual Load Report.